Tuesday, August 10, 2010

Data Classification - a key vector enabling rich Security and Privacy controls

In this article I will introduce the concept of Data Classification, what it means to Healthcare IT, and how it can enable rich Security and Privacy controls. There are many aspects to rich Security and Privacy controls, so Data Classification is not THE answer, just like Consent is not THE answer. These many aspects of Security and Privacy controls work together.

The concept of Data Classification is not new, it has been around for likely thousands of years. The idea is that some data is rather PUBLIC and can be exposed to anyone, while other data is very SECRET the kind of data one would only share with a very small number of people. I am not going to say that this concept has been around since the XXX ages, because I don't know and don't think it is important to look it up. I am sure you can look down in the comments and someone will have done the research and they should get credit. I suspect this could be seen back thousands of years.

There is much talk in the US healthcare initiatives about "Segmentation". Segmentation is typically what ones does to physically separate different Data Classifications. I think it is being spoken about in the US healthcare initiatives more as a direct synonym to what the classic Security community sees as Data Classifications. Even if Segmentation is the classic idea of physically separating data of different Data Classifications then we need to understand Data Classifications. I will assume that the word "Segmentation" is being used so as to not to be confused with Military Classification Levels. They have the same goal, but there are individuals that can't grok.

One of the models that has received the most visibility (ahem) is the Military "Classification Levels". We have all seen movies where there is a piece of paper or folder with the word "Top Secret" stamped across it. This is a 'Classification' of the content of the paper/folder into one of the various Classifications. Typically there are 5 classifications that we are use to seeing: Unclassified, Restricted, Confidential, Secret, and Top Secret.  We all know from the movies that Unclassified documents are available to everyone, yet Top Secret documents can be seen only by a very few.

This label on the document is 'metadata' that is carried by the document. This metadata is an outcome of the classification step, and is an independent step from provisioning of a user into Roles and roles into Permissions. Thus there is independent processes for classifying data, and for assigning permissions that a specific user has.This use of metadata also decouples the data from the transportation mechanism, as no matter what way that document is transported the metadata that explains the classification is attached.

Confidentiality Code

Healthcare Standards have our own version of this, the confidentialityCode. Looking at this today, we would likely pick a different name, but this is the one we got. Almost without exception healthcare standards have a confidentialityCode associated with all objects. This is true of HL7 CDA (CCD), HL7 v3 messages, and HL7 v2 messages. This is true of DICOM objects. This is true of IHE XD* metadata about documents. This is a universal place to hold the sensitivity classification of the object. This is a way that a sender can inform a receiver of how to handle the data in their access controls. This is a way that a publisher of documents can indicate the sensitivity classification of a document.

Unfortunately the vocabulary for the confidentialityCode needs some work. I say unfortunately, but in reality this reflects that we have not been able to look at this value very consistently. So today the vocabulary for confidentiality code is part Sensitivity Classification, and part Confidentiality Classification. These are not necessarily incompatible ideas, but they are trying to encode in the same value something different. Where as Sensitivity Classification would say this is "Secret", the confidentiality code would explain why it is secret (i.e. HIV).

My experience is that most implementations understand this, and choose a small subset of the existing confidentialityCodes and use them as Sensitivity Classifications, similar to the Military Classification.Note that like with the Military Classifications, these are clearly increasing in sensitivity and don't expose 'why' the classification is given. There are other codes, but they are inconsistent with Segmentation. I recommend against using the other HL7 confidentialityCodes (e.g. HIV, PSY, SDV).

Useful Value-Set from the HL7 ConfidentialityCode vocabulary (2.16.840.1.113883.5.25)
L -- Low -- Low sensitivity,
N -- Normal -- Normal clinical data to be handled by normal 'good health care practice' rules
R -- Restricted -- Restricted clinical data, restricted to those having a care relationship
T -- Taboo -- Information not to be discussed with the patient

The process for establishing an objects confidentialityCode must be inclusive of the healthcare organizations evaluation of how sensitive the information is AND how the patient would evaluation how sensitive the information is (See Magic section below).

Redaction

Add we even have seen where documents with high classification levels are "Redacted", and the Redacted version of the document is considered of a lower classification level. For example when someone makes a request for release of a highly classified document, large segments of the document may be blocked out. These large blocks of text might be specific names of individuals that were involved but who were not considered important to the message of the text.

When the identifiers are being Redacted, we in healthcare should see this as De-Identification. That is the idea that one can remove the identifiers from health information and thus the information becomes less 'sensitive'. I very much believe in the ability to use De-Identification to provide new-life to the data, but also know many ways in which it can go wrong. See De-Identification is highly contextual.

Clinical trials is a domain where there is funding and motivation to establish meaningful redaction and transform profiles that can provide automatic processing. It has been common for years to use manual Redaction (Paper and Film) on the data shared with a clinical trial. This is not just for Privacy reasons, but also for the clinical trial integrity (blinding of factors other than the one being studied). This experience with Redaction has resulted in updates to standards such as DICOM supplement 143. An important distinction that clinical trials has is that it is very clear what the purpose of the specific clinical trial, what data is needed, and what data is not needed; this is not true in general healthcare.

Removal of the sensitive information is a very useful tool. Done wrong, it can be a very bad tool. There are plenty of examples of where someone has 'thought' they had done proper redaction, but it turned out to be simply a display layer where the actual sensitive information was still present. 

Transforms

Redaction can be used in a different way that is highly useful. One might remove the most sensitive information from a document leaving just the critical health values. This form of Redaction is often seen as a "Transform" of the data. When the data is in XML form, this form of Redaction is quite easy. One must be very careful to only allow information into the transform that is well-known to be safe. This means that any free-text fields need to be blocked.

One of the most talked about health documents today is a C32. A C32 is a Medical Summary, the content may include administrative (e.g., registration, demographics, insurance, etc.) and clinical (problem list, medication list, allergies, test results, etc) information. Generally this is a minimum of clinical information that is needed by almost every care giver. Although this document is not about a specific episode of care, it could contain information that is highly sensitive. It is possible to provide two documents, one with the highly sensitive information and a transform that has removed this highly sensitive information. The system doing the publication of the document knows best what information is specifically sensitive, so it is uniquely qualified to publish these two different documents. These documents could then be Segmented or Classified differently.

In the context of XDS, the original document could be registered with a "R". The Transform could be registered using the XDS relationship of Transform with a "N" classification. In this way someone can see that the two documents are related and access the one that the user is authorized to view. This publication of two independent but linked documents may be preferred by those that want to Segmentation as there is a clear line between the two documents. This eliminates the need to perform a transform at retrieve time, and reduces the risk of accidental inappropriate disclosure. For example the audit log clearly indicates which of the two documents were used vs relying on a real-time transform.


Enabling Policy

Just like how the Military Classifications allow them to separate the act of classifying data from authorizing individuals, so does the confidentialityCode. So, lets look at a simple Truth-Table. Note that I added "Research Information" . This just to show that the limited set of confidentiatlityCodes can be extended. So imagine information marked with Research Information is specifically published for research use. This Truth-Table also shows the results of a set of Policies.

.                                   ConfidentialityCode

Functional Role
L N R T Research Information
Administrative Staff X X
Dietary Staff X
General Care Provider X X
Direct Care Provider X X X
Emergency Care Provider X X
Researcher X
Patient or Legal Representative X X X

It is very possible for a Patient Consent to directly influence these. For example the patient may be given the ability to provide their Preferences for this Truth-Table, and if accepted that would become the Policy for their data. Thus the Consent Policy becomes the Truth-Table for that patient's data.

There could be a different Truth-Table for "Emergency Mode" of operation, such as under natural disaster like Katrina.

Magic:

The unsaid magic in all of this is that there is no well-known mechanism today to automate the Data Classification. We have the place to store and communicate the Data Classification in the confidentialityCodes, but we don't have rules to use to determine if the object should be described as R rather than N. We have Consent Directives that can explain how to handle these differently categorized data, capturing the truth-table. But we do not have a good way to determine for any given object, what should the confidentialityCode be. We leave this as a task for anyone publishing data. The one creating a document or object is the one most aware of the information that is in the document or object. Today this is the individual or system that is expected to make the hard decision. In XD*, the confidentialityCode is mandatory. Most simply say "N".

We do have some regulatory assistance. In the USA 42 CFR Part 2 "Confidentiality of Alcohol and Drug Abuse Patient Records" makes it clear the types of things that we should certainly mark as "R". But even with this very specific regulation text, it is hard to be exact. Often times when one thinks they have a well-known set of rules, a doctor will come along and indicate that the combination of three factors would indicate that a patient is HIV positive. The combination become really hard to track down.

This Magic is likely to continue for sometime. Is this a bad thing? It is bad in that it is a part of the process that is not deterministic, so yes we want it fixed. Many organizations have tried to come up with a way to do this. Ultimately we would like to encapsulate the rules that patient wants used to determine the Data Classification in a Patient Preference or Consent. This is ongoing standards work.

Usually the magic is the publishing doctor selecting a radio-button: R vs N. They are usually right.

Conclusion:

For now, I just want to get confidentialityCode used. Having information differentiated by the Data Classification enables Role-Based-Access-Control. Without it, all data is seen as viewable by everyone.

Resources:
My Blog

    Sunday, August 8, 2010

    President's Council of Advisors on Science and Technology - another dissapointment

    On July 16th the President's Council of Advisors on Science and Technology (PCAST) held a webcast where the afternoon agenda was a report out "Health Information Technology Study". This report was put together over 8 months by Christine Cassel, M.D., president and CEO of the American Board of Internal Medicine; William Press, University of Texas Professor of Computer Sciences; and Craig Mundie, Microsoft's Chief Research and Strategy Officer.

    I saw ONE writup on the session: Calls for Privacy, Quality in PCAST Report  by Healthcare Informatics. There was not that much information given in the article, but it did get me interested in what Privacy aspects might have been brought up. 
    University of Texas’ Press spoke about privacy considerations with electronic health records and mentioned the saliency of a 2006 Marco Foundation survey in which 80 percent of those respondents said they very concerned about theft or fraud of electronic health records. “From the very beginning of our discussions and of the working group's discuss we realized that privacy and security couldn't be add-ons to any system of healthcare exchange,” he said. “They had to be engineered in from the very start.”

    So I went and listened to the Webcast. Fortunately it took only 50 minutes for the presentation, questions, and approval of the document. A document that is still not yet available today. My impression from the webcast is that they were given good and wonderful news about what could be. They held up VA and Kaiser as examples of comprehensive EHR systems. Yet they also referred to the original Markle Foundation report, and other studies from 5+ years ago. I further had my hopes dashed by comment after comment that showed that they had not learned anything new, but were simply making the same old mistakes over again. This has nothing bad to say about VA, Kaiser or Markle; These are all good things. What was disappointing is that the workgroup had not dug deep enough to have learned about the problems that we are all working had to solve today.

    The positive that could come out of this is more visibility into and by ONC. However frustrated I am at what ONC does, they are at least in the trenches with the rest of us working toward a solution. I will always back those that are working toward a solution, even if they might be frustrating me by not simply doing it 'my way'.



    report

    Tuesday, August 3, 2010

    Meaningful Use Security Capabilities for Engineers

    The Final Meaningful Use standards and certification are out. They are not the best written my comments and rants that Meaningful Use Security Capabilities are Lacking, Privacy Capabilities NON-existent. Today I want to point out what the Meaningful Use Security and Privacy requirements are in language that EHR engineers can understand. What you are going to see is not exactly the minimal necessary for MU, but rather my recommendation relative to the specific items. This is similar to my  Comments on the IFR Security/Privacy.

    Meaningful Use does require that the deployment use Risk Analysis as the method to select the technologies that are actually used. What this means is that the operational environment will likely need capabilities well beyond anything mentioned in the standards and certification criteria. The good news is that the certification is going to focus less on these criteria. These criteria are, as I mentioned before, the typical ones found in the CCHIT and NIST SP 800-53 “Recommended Security Controls for Federal Information Systems and Organizations” (http://csrc.nist.gov/publications/PubsSPs.html).

    The things that you are going to be tested against are the Meaningful Use Standards

    Specific Requirements


    • §170.210 (a) - Encryption and decryption of electronic health information
      • FIPS 140-2 Annex A allows for 3DES or AES.
      • Many encryption solutions are provided by the platform (transparent hard-drive encryption, encrypting USB-Memory, S/MIME or PGP email) or network (VPN, IPSec). These solutions are very effective and do NOT require that the EHR technology be aware of the technology. By placing an encryption requirement on the EHR technology, they are proposing that the EHR solution provider involve themselves in a way that removes flexibility currently available to an operational environment.
      • It appears that Data-At-Rest is expected to be in scope. Leverage built in Database encryption or Transparent Hard drive  encryption. 
        • Hopefully the EHR can specify a 'class of off-the-shelf hard drive encryption products' rather than having to specify a single one.
      • Have the capability to cover all network communications that include PHI with Mutually-Authenticated-TLS as is the specification in IHE ATNA

    • §170.210 (b) Record actions related to electronic health information
      • Future certification should and likely will require the ATNA message/transport to those that are representative of the transactions that cross the organizational boarder (meaning they are subject to Meaningful Use).
      • Today one must simply record the security audit events. The date, time, patient
        identification, and user identification must be recorded when electronic health
        information is created, modified, accessed, or deleted; and an indication of which
        action(s) occurred and by whom must also be recorded.
    • §170.210 (c) Verification that electronic health information has not been altered in transit
      • See §170.210 (a) - Encryption and decryption of electronic health information
    • §170.210 (d) Record treatment, payment, and health care operations disclosures
      • Have the capability to record a 'disclosure' event. Meaning add a user interface specifically for doing nothing but capturing the event
        • The date, time, patient identification, user identification, and a description of the disclosure must be recorded for disclosures for treatment, payment, and health care operations, as these terms are defined at 45 CFR 164.501.

    and

    • §170.302 (o) Access control. Assign a unique name and/or number for identifying and tracking user identity and establish controls that permit only authorized users to access electronic health information.
      • Have the capability to differentiate a reasonable set of roles for your application workflows. Some applications will logically have many (doctor, nurse, dietition), while some specialized EHR or Modules will have few.
      • Have the capability to differentiate the level of access these roles have. Again this is going to be highly dependent on the product type.
    • §170.302 (p) Emergency access. Permit authorized users (who are authorized for emergency
      situations) to access electronic health information during an emergency. 
      • Note that 'emergency situations' is NOT the people scheduled to work in the Emergency Room.  This is normal Access Controls, as this is the normal workflow for these people
      • An Emergency is a truely exceptional condition as defined in HIPAA. Your product may not actually have any of these. 
      • Some EHR may have a permission that can be assigned to individuals or roles that allows for 'Break-Glass'.
    • §170.302(q) Automatic log-off. Terminate an electronic session after a predetermined time of
      inactivity. 
      • I really hope they don't test to this criteria as written, as it is really counter to workflows that require continunity where a screen-blank functionality would be preferable to anyone.
      • The point is the same point in HIPAA.. When the system detects that there is no user activity, then it is likely there is no human present and thus to prevent the currently displayed data from being exposed to the user something must be done. 
      • Do the right thing for your workflows.
    • §170.302 (r)  Audit log. 
      • (1)—Record actions. Record actions related to electronic health
        information in accordance with the standard specified in §170.210(b). 
        • See above §170.210 (a) - Encryption and decryption of electronic health information
      • (2) Generate audit log. Enable a user to generate an audit log for a specific time period and to sort entries in the audit log according to any of the elements specified in the standard at §170.210(b).
        • I read 'generate audit log' as 'create a report from the audit log'.
        • I am not sure all the elements are really that important to sort on.
        • Have the capability to produce reports based on the audit log
    • §170.302 (s)  Integrity.  
      • (1) Create a message digest in accordance with the standard specified in §170.210(c).  
        • See above §170.210 (a) - Encryption and decryption of electronic health information
      • (2) Verify in accordance with the standard specified in §170.210(c) upon receipt of
        electronically exchanged health information that such information has not been
        altered. 
        • See above §170.210 (a) - Encryption and decryption of electronic health information 
      • (3) Detection. Detect the alteration of audit logs. 
        • Audit Logs need to be protected against inappropriate modification or purging. Thus the Audit Logs need to be protected using the same level of access controls as any PHI
    • §170.302 (t)  Authentication. Verify that a person or entity seeking access to electronic health information is the one claimed and is authorized to access such information. 
      • There is no guidance here, so have some User Authentication mechanism.
      • I might stretch this item to indicate that this is why you must do Mutually-Authenticated TLS on the network as well.
    • §170.302 (u) General encryption. Encrypt and decrypt electronic health information in accordance with the standard specified in §170.210(a)(1), unless the Secretary determines that the use of such algorithm would pose a significant security risk for Certified EHR Technology. 
    • §170.302  (v) Encryption when exchanging electronic health information. Encrypt and decrypt electronic health information when exchanged in accordance with the standard specified in §170.210(a)(2). 
      • See above §170.210 (a) - Encryption and decryption of electronic health information  
    • §170.302 (w) Optional. Accounting of disclosures. Record disclosures made for treatment, payment, and health care operations in accordance with the standard specified in §170.210(d).
      • See above §170.210 (d) Record treatment, payment, and health care operations disclosures
     
    Missing Requirements

    If the certification requirements are to be complete set of functional requirements, then there are many requirements missing. In the early years of CCHIT I was co-chair of the Security Workgroup and lead CCHIT effort to define a set of comprehensive yet reasonable requirements for a secure Health IT system. These requirements have been very carefully crafted to not interfere with healthcare workflows, implementations, or the creativity of the EHR vendor.

    In some cases these are requirements for specific documentation from the vendor. This is a good way to support the communications between the vendor and the operational environment. These documentation requirements ultimately force the vendor to think beyond clinical functionality and make declarations on security topics including such non-functional aspects as hardening the system to network attack.

    Without these additional requirements I am concerned that the IFR will leave the false impression that a system certified to the criteria is secure. If these additional requirements are not also included then I would recommend that the security requirements be totally removed. The Operational environment is already required to meet the HIPAA Security requirements that are based on Risk Assessment and Mitigation. This is a far more comprehensive and reasonable approach.

    Privacy Consent

    Totally absent is Privacy, not even opt-in or opt-out Consent. I think that BPPC can and should be used to enable OPT-IN in an XDS like RHIO (HIE/HIO). This is not to say that BPPC is the long term solution, but without an OPT-IN ability we will get nowhere on deploying the Health Internet. BPPC is 'good enough', and is a logical path toward something more advanced. HL7 is already working on that more advanced solution, and it is a logical extension to where BPPC is today.



    Although not required, I recommend that for HIE operations an EHR be capable of supporting Stepping stones for Privacy Consent

    ITI Call for Proposals Opens and Invitation to the ITI Planning Meeting October 18-19, 2010

    It is with great pleasure that we announce the IHE annual planning cycle kick off beginning in August 2010, and continuing through October 2010. This e-mail describes the ITI planning cycle process.

    IHE ITI Call for Proposals: Interested parties are invited to submit proposals for new Profiles and/or White Papers for the IT Infrastructure (ITI) Domain to be considered for development in the 2011-2012 cycle.  Additionally, all IHE members are invited to forward this announcement to their committee mailing lists and other interested persons.
    The deadline for submission of a proposal for new Profiles is September 17, 2010, at 11:59 pm CST.  
    Proposals must follow the structure and format of the Brief Proposal Template attached, specifically addressing the following:
    1. What is the problem you propose to solve by this proposal, and how is that problem expressed in practice? (eg. a use case)
    2. How would fixing this problem improve health care in practice?
    3. What specific components of standards could be used to solve this problem?
    4. Include some indication of the business case surrounding the situation if possible. For example, is there an economic motivation for addressing this problem immediately?
    5.  Identify one or more potential editor(s) in the event that the proposal is selected for further evaluation and possible development. 
    Please use the attached Brief Profile Template to submit your proposal.  Alternatively, and for those who are comfortable documenting on the Wiki, you may also submit your proposal using this Wiki page template found here or visit: http://wiki.ihe.net/index.php?title=Brief_Proposal_Template. Don’t forget to follow the template instructions, and to save your proposal on the Wiki using a unique NAME.

    Email Completed Proposal documents (or the link to your completed proposal on the Wiki) to both ITI Planning Co-Chairs and HIMSS secretariat: 
    ·         Michael Nusbaum: Michael@mhnusbaum.com
    ·         Charles Parisot: Charles.Parisot@med.ge.com
    ·         HIMSS Secretariat: ihe@himss.org


    Invitation to attend IHE ITI Planning Committee meeting:  Monday & Tuesday October 18-19, 2010 
    The meeting RSVP survey link, hotel accommodations, and agenda will be sent out the week of August 9, 2010. Please save these dates on your calendar by opening the ICS calendar invite that is attached to this email.
    Dates: October 18 – 19, 2010
    Location: Radiological Society of North America
    820 Jorie Boulevard , Oak Brook, IL  60523 Phone: (630) 571-2670
    The ITI Planning Committee will hold its 2011-2012 planning meeting on October 18-19, 2010 at RSNA in Oakbrook IL. A preliminary agenda of our activities will be sent out after the September 17th deadline, however, history has indicated that our time during the days is flexible and depends on the nature and number of profile proposals. The ITI Planning Committee will vote on the final selection of short-listed proposals at this meeting to move forward for submission to the ITI Technical Committee.
    We urge those who propose profiles or white papers to attend the Planning Committee meeting either in person or by phone. In-person advocacy has proven to be especially effective in getting proposals understood and accepted.  We have a relatively short window for turn-around of the detailed proposals for the items selected for this year's cycle so acceptance of proposals depends heavily on the Planning Committee's consensus about the market needs, relative priorities, and level-of-difficulty of all profile proposals at this face-to-face meeting.
    IHE membership is required to attend or participate in the ITI Planning face-to-face meeting, and to submit votes on October 18-19, 2010.  If you are unsure your organization is an IHE member, please check the membership list. If you would like to apply for membership, please visit this webpage. 
    In order to participate in meetings, you must first be a delegate of an approved IHE member organization.  Membership is granted only to “organizations” and each member organization names delegates to participate in various domain committees.  Please check the membership list to ensure your organization is a bona fide member of IHE. If not, then you can apply for membership (it’s free) using this webpage.
    ITI October face-to-face Planning Meeting participation: Any member is entitled to send a delegate to attend a meeting. However in order to vote, the member (organization) must have earned (and maintained) voting privileges prior to the designated meeting.  The rules around voting privileges are articulated on the IHE website.  

    ITI Planning Webinars (Prior to the face-to-face): ITI will schedule four Planning Webinars prior to the October meeting to allow authors to present their proposals to the ITI Planning Committee in advance of the face-to-face. This procedure also allows all Planning Committee members to re-establish their voting rights. We have established specific procedures for the Planning Webinars, so please make sure you understand and follow the instructions below to ensure you will have the right to vote at the meeting. 
    1.       ITI Planning Webinars have been tentatively set for the dates listed below. The exact dates and times will be sent out as soon as possible. We will populate the schedule of presentations immediately following the September 17th submission deadline.
    §  The ITI Planning Webinars will run during the following weeks:
    §          September 27 – October 1, 2010
    §          October 4 – October 8, 2010
    §          Webinars will be two hours long with 6- 15 minute profile presentations
    2.       These webinars will be considered decision meetings.  We will attempt to reach consensus (rather than hold a formal vote) at each webinar as to the validity of each individual proposal, including whether it makes sense to request proposal authors to combine initiatives where overlaps exist.  No proposals will be rejected at this stage, only aligned with one another, and only where appropriate.
    3.       In order to ensure voting privileges at the October face-to-face Planning meeting in Oakbrook, we will require each member (organization) to attend a minimum of 2 (out of the 4) webinars that precede the meeting.  We will be taking very careful attendance at each webinar to ensure a fair execution of this process.  Please ensure you clearly understand this requirement.
    4.       Committee rosters can be viewed on the FTP site at: ITI Rosters


    ITI Planning Webinar Procedures:  Each webinar will be organized as follows (this will vary slightly depending upon how many proposals we will be reviewing):
    1.       The two hour time allocation will be divided into 6x15-minute time-slots, with the remaining 30 minutes for introductory remarks and follow-up discussion.
    2.       Each 15-minute timeslot will be allocated to a profile proposal. The first 10 minutes will be taken up by a presentation by the proposal author, with the remaining 5 minutes reserved for discussion and any disposition (if required).  In order to maintain equity across all presenters, we will manage this time rigorously!
    3.       Each 10-minute presentation will be comprised of a maximum of five (5) PowerPoint slides, presenting your proposal concisely and completely.  We have taken the liberty of supplying a presentation template that you may choose to use, and this can be found in the following folder on the IHE ftp site.
    4.       A sample webinar agenda is shown below (however, please note that we will assign presenters/topics to each timeslot after the September 17th deadline):
    Sample - IHE IT Infrastructure Planning Committee Webinar #1 (of 4)
    October 4, 2010 • 10am-noon Central Time
    Item
    Description
    Time
    (min)
    1
    Introduction
    10
    2
    Presentation #1 (topic, presenter)
    Discussion
    10
    5
    7
    Presentation #6 (topic, presenter)
    Discussion
    10
    5
    8
    Wrap-up discussion, disposition
    20

    5.       The final webinar will be reserved for presentation/discussion on any proposals that have been combined or otherwise re-worked as a result of discussion during the first three sessions.  We will ensure that the agenda for this session is published with as much advance notice as possible.
    6.       Each of the four webinars will be recorded with links published, so members can view (or review) the profile proposals prior to the October 18-19, 2010 face-to-face meeting.  We will also publish an agenda, together with procedures, for our face-to-face meeting.

    IHE ITI Planning Webinar Dates:
    • Webinar #1 & 2:  September 27 – October 1, 2010 – Dates and times TBD.
    • Webinar #3 & 4:  October 4 – October 8, 2010 – Dates and time TBD.
    The agenda’s for these Webinars will be sent out after the September 17th, 2010 deadline.

    If you have any additional questions please contact the ITI Planning Co-Chairs.
    Thank you for your participation and support of IHE.

    Sincerely,
    Michael Nusbaum and Charles Parisot
    IHE ITI Planning Co-Chairs 

    Webinar on the NEW work from IHE IT Infrastructure - Including updates to XUA

    This Webinar will introduce the audience to the updates done this year. Including the updates to the Cross-Enterprise User Assertion (XUA) Profile. These updates add three named options:
    • Role-Based-Access Control – option supporting specification of user roles to authorize the transaction -- Supporting role based access decisions on the service side
    • Consent/Authorization – a specific way to carry an indicator of relevant consent or authorization policies that would authorize the transaction-- Supporting push of consent policies and provider-patient relationship
    • Purpose of Use – option supporting the specification of the Purpose of Use that describes the reason for the transaction -- Supporting better Accounting of Disclosures
    • Other Descriptive Attribute to support consistent way to carry some additional descriptive values
    Here is the general information for the Webinar:
    IHE Domain- Review of IT Infrastructure Profiles & Technical Frameworks

    Thursday, August 5, 2010 at 10:30 am — 12:00 pm CST

    New & Past Participant Webinar: IT Infrastructure is one of the eleven clinical & operations domains in IHE. Learn more about the most current profiles and technical frameworks which the ITI technical committee is working for implementation at the IHE 2011 N.A. Connectathon. Note: Past profiles and technical frameworks will not be discussed in length on this webinar. Please refer to the 2008 & 2009 webinars or secretary@ihe.net.

    Speakers:
    Karen Witting, Charles Parisot, Rob Horn, Michael Nusbaum — IT Infrastructure Domain Co-Chairs

    Register Online >>

    Monday, August 2, 2010

    Stepping stones for Privacy Consent

    Over the last few weeks HHS/ONC have produced lots of reading material. I have not had any trouble falling asleep lately, but it sure is getting hard to get through all of this reading material. The executive summary is that there appears to be a reasonable and comprehensive approach to Security, but Privacy is left behind.

    That is to say that HHS/ONC have caught on to the need to use Security Risk Assessment as the prime 'framework' for Security. With the blog post EHR Security: A Top Priority by: Dr. Deborah Lafky of HHS it s clear that low-hanging fruit needs to be identified and picked. This is the lesson that I had hoped they would learn. I have seen many organizations learn this lesson, and indeed have seen many organizations have to learn this lesson multiple times. And so it is with HHS, who learned this lesson back at the original HIPAA Security rule and again now with the current set of specifications including the update to HIPAA.

    They also recognized that the Standards and EHR products need to have reasonable security 'capabilities', but that using these capabilities is a policy choice that the provider should be free to choose to do, based on their Risk Assessment. I have further drill down on the Meaningful Use Standards: Meaningful Use Security Capabilities Lacking, Privacy Capabilities NON-existent

    The bad news is that they seem to have backed off on Privacy Controls, again. I do understand why they do this, but I don't agree with their approach. What it seems to me is that they feel that if they can't do Privacy right, then it shouldn't be done at all. I think this is an approach that will lead to continued non-action. Unlike Security, that has the Risk Assessment approach to come to the rescue, Privacy is harder. But trying to slice Privacy up into digestible portions is a delicate thing.

    What should be done?

    HHS/ONC should have focused Privacy within the HIE. I understand how difficult Privacy is to deal with inside the existing healthcare provider organization. There is already policy and procedures and sometimes technology in place to deal with the HIPAA Privacy requirements. This environment is going to be hard to change, eventually it must. But it is the green-fields of HIE that need to be designed from the beginning with Privacy.

    From what I read, an Accounting of Disclosures is clearly needed for every communication of PHI in a HIE; so why not require that an EHR interacting with an HIE must record this? There are standards for this, ATNA can inform an Accounting of Disclosures. There is ongoing work to make this better and better (See the new IHE XUA++ supplement soon to be published for Trial Implementation), but the basics are in place. Accountability using ATNA Audit Controls is critical to success.


    From what I read in the HHS white paper on Consumer Consent Options, there are some basics of consent policies. Indeed going with the stepping-stones idea, why not require the standards and EHR to support blanket opt-in or blanket opt-out regarding participation in an HIE. This policy would not need to be related to any existing Provider Organizational policy, it would be restricted to the interactions with HIE.

    When I say blanket opt-in or blanket opt-out, I really mean without exceptions. I really mean without break-glass. I am too afraid to declare about Government access, such as quality reporting. Seems to me these can already be handled by access to the Provider Organization.  I have been saying this for almost a full year on this blog Opt-In, Opt-Out.... Don't publish THAT! The HIE would still need to choose if they want a default opt-in or a default opt-out; meaning an implicit consent vs explicit consent environment. Then there is the question of if opt-out means that documents are not submitted to the HIE, a very difficult topic.

    This choice of exactly 2 policies, opt-in vs opt-out, is not that friendly to those patients that want more control, but lets at least deal with those that are willing to choose YES vs NO. Today we have nothing but chaos, and chaos favors statuesque. An interesting study on the economies of privacy showed:
    "When you have privacy, you value it more,” said Mr. Acquisti. “But when the starting point is that we feel we don’t have privacy, we value privacy far less.” More
    It is somewhat unsettling that I am agreeing with Deborah Peel . Awareness of Privacy is not enough, action is necessary. I simply want to push for some achievable stepping stones that clearly head in the right direction.
    I am excited that the HIT- Security and Privacy Tiger Team has also recommended this, and More

    An excellent blog article on this topic Health IT policy intensifies focus on consent.  This article very nicely picks apart the actions going on in DC.

    Reference my blog article: The meaning of Opt-Out, Opt-In, Opt-Out.... Don't publish THAT!,  Consent standards are not just for consent, Consumer Preferences and the Consumer, and RHIO: 100,000 Give Consent.

    Sunday, August 1, 2010

    Meaningful Use Security Capabilities Lacking, Privacy Capabilities NON-existent

    I hope that anyone developing a Complete EHR or EHR Module goes way beyond the capabilities required in the Meaningful Use Standards - [Health Information Technology: Initial Set of Standards, Implementation Specifications, and Certification Criteria for Electronic Health Record Technology]. This is not just because I want to push these products beyond some bare-minimum; but rather that the capabilities that any system entrusted with objects that need protection need to go beyond the bare-minimum listed. I leave 82% of the text to people smarter on the clinical aspects such as Keith at Meaningful Use Standards Summary

    When the IFR came out I declared that Meaningful Use clearly does not mean Secure Use. I then took a step back and evaluated the criteria carefully and submitted Security/Privacy comments on the IFR. This was at the time based on the same set of gaps that still exist. To be fare the Final Rule did fix many of the problems with the text that they did have, almost a complete fix of the problems with the existing text. From my understanding of the rules, an IFR can not be radically modified or added to; so HHS was not really allowed to close the gaps that still exist.

    So, any EHR that has been designed toward a good set of security capabilities will likely have the right stuff. I think the current text is useful but still not really going to drive good product design, while it will drive unnecessary churn. If HHS had not tied their own hands with the IFR process, they could have referenced NIST SP 800-53 “Recommended Security Controls for Federal Information Systems and Organizations” (http://csrc.nist.gov/publications/PubsSPs.html). This is a very good set of criteria that has been the basis of, or derived from, many other good criteria. Most of what is in here can be found in the CCHIT security criteria as well. It is sad that healthcare seems to want to re-invent the wheel so much. My recommendation is to follow CCHIT criteria or better to follow NIST 800-53.

    I do understand the market readiness of Privacy Controls, but it hurts to see these things continually kicked down the road. I am working hard to get these standards in place, then working even harder to get the standards that we do have implemented, and eventually will work really hard to get them deployed. I think that we are close, and that MU could start pushing some of these. I hope to find some of this in stage II. Consent, even just blanket opt-in/out (blog on consent); Accounting of Disclosures (blog on Accounting of Disclosures); Data Segmentation (future blog topic); and Limited Patient Access to their records.

    Critical for everyone to recognize the certification criteria for a Complete EHR or EHR Module are ‘capabilities’. These capabilities will be chosen to be used or not based on a Risk Analysis. The Risk Analysis that has been a core of Meaningful Use and the HIPAA Security rule all along. A Risk based approach applies technology when justified. A Risk based approach does not apply technology simply for the sake of applying technology. At this point I will indicate that there are Bad and Ugly parts of the Final Rule that don’t recognize that some possible capabilities that will never be reasonably used should not be mandated.

    The following is further comments on the Final Text..

    The Good

    The good news is that they did fix some important problems
    1. They removed the whole religious war around REST and SOAP. I am sure I was not the only one to point this out to them. I am glad it simply was removed.
    2. They got less proscriptive on encryption, and chose to leverage the great work of NIST in FIPS 140-2 Annex A.
    3. They got less proscriptive on integrity controls, point at NIST FIPS and SP; but they still have some strange text that could cause unnecessary arguments
    4. They removed the requirement for the EHR to alert based on user-defined events. This is not only a very open-ended requirement (user-defied events), but is a very specific functionality of audit log analysis. Not a bad feature to have in a full featured EHR, but clearly not a minimalist requirement
    5. They added “Accessed” to the auditable events. This should have always been there, but I suspect it slipped between the terminology from multiple good security audit log standards harmonization.
    6. They removed “Print” from the auditable events. Well, they went a bit too far in the comments. Print should be recognized as a form of Export. And any time the EHR knows that it is exporting PHI is an auditable event. The comments were about all the edge cases where the EHR is unaware of a export, such as taking a picture of the screen. This is far better handed through a clear distinction that auditable events are those events that the EHR is in control of. This clearly makes it obvious that an event that the EHR can not control couldn’t possibly be audited by the EHR.
    7. They dropped the Cross Network Authentication. I very much agree that XUA/SAML is not ready to become a certification criteria. But I had recommended that they recast this requirement so that communications going between organizations are authenticated organization-to-organization, essentially what ATNA requires in mutually-authenticated-TLS. There is no requirement for this level of authentication in the criteria.
    8. Accounting of Disclosures is optional – We all know that indicating that this is optional is as good as removing it. This one is hard to say is a good thing, because Accounting of Disclosures is so critical to Privacy; but the facts are that the standards are still being developed and that the Accounting of Disclosures that can come from the EHR is a reporting function of the Audit Log Management. The reality is that most actual Disclosures are not detectable by an EHR as they are events at the organization level. Thus the actual Accounting of these Disclosures is a higher level function than an EHR. Good Blog by Security Architecture This unrest is further expressed by this weeks announcement that HHS pulled the Health Data Breaches Proposed Final Rule from OMB review. No news yet on why.

    The Bad


    The Bad news is that there is still some small problems. None of these is really critical or going to cause trouble. Again reasonable minds will come to the same and right conclusion. So, don't worry too much about these items.
    1. They are timid about Security Audit Logging. Not only do they reject ATNA, which is likely the right choice for now (but not for the reason they give); but they also fail to recognize critical auditable events. An Emergency Access override should clearly be an auditable event.
    2. No change to Automatic log-off – Yes automatic log-off is needed, actually HIPAA has this covered and covered better. Termination of a session is excessive, removing access to PHI after inactivity is not.
    3. The Encryption and Integrity Controls are still messed up. Yes it is great that they are referencing the good work of NIST. But they are still too prescriptive on how to use these cryptographic algorithms. They needed to take a step back and abstract further. Fact is they should have abstracted as far back as HIPAA. The only reason that Encryption or Integrity Controls should have been mentioned was to specify some minimum Interoperability criteria. This would have required that they indicate a protocol, such as TLS. For some reason they were afraid of this. The point would have been that the EHR have the ‘capability’ to use TLS, not that TLS was the only operational choice.
    4. Detection of alterations of the audit log – This has got to be the strangest criteria I find. I have nothing against protecting the audit log from alterations. BUT, why only protect the audit log? Why did they remove all the other things that should not be modified without authorization? Actually the detection is of all alterations, not unauthorized ones, thus any event that is recorded will alter the audit log by being appended to it and this will cause an audit event that the audit log was altered which will be appended to the audit log which will be detected… THIS CRITERIA MANDATES THAT THE EHR GOES INTO AN INFINITE LOOP! The line should have been removed.
    5. As indicated in (6) above; there is no requirement that systems talking across the internet authenticate themselves. I suspect this is an obvious gap that everyone will fill it. But it is an example of how the criteria are too low level. A simple ‘secure communications using open-standards’ could have solved this completely.
    6. Authentication is not Authorization – this is a pure nit… The Authentication criteria should be only about authentication, and not have added authorization to the task. Authorization is already handled
    7. Encryption of all network communications involving PHI. There is lots of comments on this one, and I disagree with the conclusions. Today PHI travels securely through many different ways, some private networks. The rule should have limited the scope of these transport encryption and integrity controls to the NEW communications requirements of Meaningful Use. This scope would have focused attention ‘green fields’. This is not to say that the old communications couldn’t be improved upon, but they would be improved at a more reasonable pace. As written the EHR must be able to add encryption to all communications, some communications that no Provider will use this new encryption capability because they already have a secure communications.
    8. Transparent security capabilities – This goes with many of the points above. Security is often implemented in transparent layers. No developer spends any effort on developing code that checks that data base entries have been inappropriately modified; this has been a common database tool functionality for a decade. Indeed the requirement for SHA1 to be used could have developers spending lots of time trying to figure out if their database tool uses SHA1. If it is found that SHA1 is not used, then what? How is the developer to evaluate the difference? This is wasted time!!! I suspect that most will understand this as a waste of time. I will then assert that the same is true about other security capabilities. For example Hard-Drive Encryption. It is quite common now days to add a transparent hard-drive capability to a laptop. When this is done all applications on the laptop are protected, and actually these applications can NOT tell. So, requiring an EHR to have hard-drive encryption is going to drive unnecessary waste of time and energy. What about the use of VPN to provide transparent network security? These are far better implemented as transparent security capabilities in the organization level not in the EHR. I would like to push more and more in here as well including User Authentication, Node Authentication, and eventually much more.

    The Ugly

    The General Encryption rule has conditionals “unless the Secretary determines that the use of such algorithm would pose a significant security risk…”. This is wrong on so many levels. Why is this the Secretary role? Isn’t this the Risk Analysis role? The whole “General Encryption” criteria changes the game from a case where the Risk Analysis determines when a technology (like Encryption) is necessary; to a case where Encryption must be presumed needed unless the Secretary determines that it is not needed. Does this mean that the Secretary is going to evaluate each time a patient gets harmed because data could not be legitimately used? I really hope this one gets corrected somehow, and quickly.

    Etc

    Medical Records Retention requirements seem to be touched upon, but not fully. Change Tracking is not a security audit log scope, but it is a Medical Records Retention requirement. The HL7 EHR Functional model spent lots of time fully understanding Medical Records regulations as well as their separation from Security requirements.